Volume - 13 | Issue-1
Volume - 13 | Issue-1
Volume - 13 | Issue-1
Volume - 13 | Issue-1
Volume - 13 | Issue-1
A simple, cost-effective, stability-indicating, rapid method has been developed for the estimation of Favipiravir (FVR) in FVR drug products. The method developed is specific, precise, accurate, and linear. The analyte was quantified using an octadecylsilane HPLC column. The chromatographic conditions employed peak detection at 365 nm. The mobile phase used was Water: Methanol: Ethanol in the ratio of 60:20:20. The pH was adjusted to 3.0 to achieve better peak symmetry